PremiSys Wi-Q - Setup and Usage of Manager Mode

Manager Mode

A cardholder with Manager authority is always allowed access to a reader regardless of the current operating mode. In addition to unlocking a “locked” door, a Manager can change the current operating mode at a door lock with a keypad. The manager card must be part of an access group that includes the Wi-Q doors.

Click below for manager mode setup instructions.

Manager mode Setup
1. Manager Mode requires creating a User Level and the Name field needs to have the value of “1”

2. In PremiSys go to Tasks - Hardware Configuration - Access Settings Tab - Right-click the User Level(s) folder. Select Add User Level.

3. Add the Name as "1" as shown in the image below. Click Ok to close the window.

4. Open a cardholder record on whom you would like to set up as a Manager mode card. Once the record is open, click on the card configuration at the bottom. Right-click the card number and select Edit Card.

5. The Card Properties window opens, Click the User Levels Tab. A Manage Mode Card requires the above user level to be assigned to Slot 6.


6. Click OK and Save the Record.
***Please note the manager card must be part of an access group that includes the WI-Q doors.***

Once their credential has been presented to a lock and it has cycled, the following keys can be used to change the lock’s operating mode: 

Item

WDC

WAC

Function/ Mode

Manager Code

Swipe

Swipe

Momentary Unlock

Restore to Normal

Swipe + 0#

Swipe + 0000

Return to normal operation from an override

Toggle

Swipe + 1#

Swipe + 1111

Places the lock in a mode where it toggles between locked and unlock with a cardholder swipe. Not a mode normally supported by Mercury.

Unlock

Swipe + 2#

Swipe + 2222

Places the lock in an unlocked state

Unlock with ID

Swipe + 3#

Swipe + 3333

Card-only mode

Unlock with Card and PIN

Swipe + 4#

Swipe + 4444

Card and PIN mode

ID Required 

Swipe + 5#

Swipe + 5555

Card or PIN mode

PIN Required

Swipe + 6#

Swipe + 6666

PIN-only mode. Not a mode normally supported.

Facility Card

Swipe + 7#

Swipe + 7777

Facility Code Only mode

Lockout

Swipe + 8#

Swipe + 8888

Locked mode. REX active for a WAC

Toggle with Card and PIN

Swipe + 9#

Swipe + 9999

Toggle between locked and unlocked with a Card and PIN. Not a mode normally supported by Mercury