PremiSys Wi-Q - Setup and Usage of Programmer Mode
Programmer Mode
A cardholder with Programmer authority is always allowed access to a reader regardless of the current operating mode. In addition to unlocking a “locked” door, a Programmer can perform a motor test or various reset operations. Once their credential has been presented to a lock and it has cycled, the following keys can be used to perform the programmer functions:
Click below for Programmer mode setup.
Programmer mode Setup
2. In PremiSys go to Tasks - Hardware Configuration - Access Settings Tab - Right-click the User Level(s) folder. Select Add User Level.
3. Add the Name as "2" as shown in the image below. Click Ok to close the window.
4. Open a cardholder record on whom you would like to set up as a Programmer mode card. Once the record is open, click on the card configuration at the bottom. Right-click the card number and select Edit Card.
5. The Card Properties window opens, Click the User Levels Tab. A Programmer Mode Card requires the above user level to be assigned to Slot 6.
6. Click OK and Save the Record.
***Please note the programmer card must be part of an access group that includes the WI-Q doors.***
Once their credential has been presented to a lock and it has cycled, the following keys can be used to change the lock’s operating mode:
Item | WDC | WAC | Function/Mode |
Programmer Code | Swipe | Swipe | Momentary Unlock |
Soft Reset | Swipe + 1# | Swipe + 1111 | Soft resets the device |
Motor Reset | Swipe + 2# | Swipe + 2222 | Resets the motor drive |
Comm. Processor reset | Swipe + 7# | Swipe + 7777 | Resets the communication processor |
Motor Test | Swipe + 8# | Swipe + 8888 | Runs a motor test |
Deep Reset | Swipe + 9# | Swipe + 9999 | Deep (factory) resets the device |